
Domes 23 April 2002 I.James
Version 1.3 Page 24 of 29 E & OE
Pelco Spectra II SD5 Dome
This has its own Dome menu that can be accessed by the DS with Application software 2.0 (021)
or above.
Dome features via DS:
Variable P/T/Z
Full menu operation.
64 presets.
RS422 2 wire Control
Randon Scan
Auto Scan
Frame Scan
Dome Connection
Connection from the Digital Sprite is from the Serial 9 way D- type Female to the Pelco Mounting
Base Board.
Must be set for Pelco 'P' protocol and 9600 Baud.
See Pelco Installation guide for more information.
Digital Sprite - 9 Way D-Type
Female
Pelco RS422 Data Port
Pin 1 Data A + Control Rx +
Pin 9 Data B - Control Rx -
Not connected Control Tx +
Not connected Control Tx -
SW-1 Protocol Selection DIP switches
"P" Version On Off Off Off Off Off Off Off
Dip Switch 1 2 3 4 5 6 7 8
SW-2 Address DIP switches
"P" Version
Rx Address = Switch Value plus 1
Dip Switch 1 2 3 4 5
RX Address 1 Off Off Off Off Off
RX Address 16 On On On On Off
Switch Value 1 2 4 8 16
Dip Switch 6 7 8
9600 Baud Off On Off
Once the dome has been powered up the screen will say.
PELCO SPECT II 3.31
CONFIGURE DOME
Protocol P
Address 1
Comm 9600,N,8,1
Comentarios a estos manuales