Assigning keys to operate relay outputs (CNT-CLS 1-2)
It is possible to assign the <Wash>, <Wipe> or <Lamps> keys to operate different Relay outputs
on the Alarm Output connector.
Default Settings.
DM Key Panasonic function
<Lamps> , latching ON/OFF Not assigned
<Wash>, momentary close Close Aux 1 output
<Wiper>, latching ON/OFF Close Aux 2 output
Enter the Domes menu press the <* Command> button. A key assistance box appears which
says which keys are used to navigate the following dome menu, press <Menu> to continue.
To assign a keyboard button to a Relay output press the <CAM 1> key then press the key you
want to assign to Aux. 1 output. E.g. Press <CAM 1> then <Lamps> . This will assign the
<Lamps> button to operate the Panasonic's Relay Output 1.
Repeat the same process as above but use the <CAM 2> to assign the key to Panasonic Relay
Output 2.
Once the keys have been assigned exit the dome menu by holding down the <* command>
button.